BNTHY - ALKYD ENAMEL GREEN 14516

  • MSDS: BNTHY
  • Manufacturer: TRIANGLE COATINGS INC
  • Product Name: ALKYD ENAMEL GREEN 14516
  • National Stock Number: 8010-00-584-3329
Product Identification

Product ID:ALKYD ENAMEL GREEN 14516
MSDS Date:10/07/1991
FSC:8010
NIIN:00-584-3329
MSDS Number: BNTHY

Responsible Party
TRIANGLE COATINGS, INC.
1930 FAIRWAY DRIVE
SAN LEANDRO, CA 94577
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 415-895-8000

Preparer: JBR

Cage: 0GB20

Contractor
TRIANGLE COATINGS INC
SAN LEANDRO, CA 94577-5631 US

Telephone: 800-895-8000

Cage: 0GB20

Ingredients

VERY LONG OIL ALKYD (SARA 313) (VAPOR PRESSURE 6.8 MM HG @

Fraction By Weight: 35%

ACGIH TLV: 100 PPM


ZINC OXIDE (SARA 313)

CAS: 1314-13-2

RTECS: ZH4810000

Fraction By Weight: 10%

OSHA PEL 15MG/M3 TDUST/5 FUME

ACGIH TLV: 10MG/M3 TDUST; 9293


HYDROCARBON MIXTURE (VAPOR PRESSURE 2.0 MM HG @ 20C)

CAS: 64741-41-9

Fraction By Weight: 20%

OSHA PEL 100 PPM

ACGIH TLV: 200 PPM


1.97 LB/GL (237 G/L)

RTECS: 9999999VO

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE TOXICITY: OVEREXPOSURE CAN LEAD
TO CENTRAL NERVOUS SYSTEM DEPRESSION PRODUCING SUCH EFFECTS AS
HEADACHE/DIZZINESS/NAUSEA/LOSS OF CONSCIOUSNESS. EYE: SHORT-TERM
CONTACT-SLIGHT IRRITATING. PROLONG /REPEAT CONTACT: MORE
IRRITATING. SKIN:PROLONG/REPEAT LIQUID CONTACT CAN CAUSE DEFATTING
AND DRYING OF THE SKIN WHICH*
Effects of Overexposure:*MAY RESULT IN SKIN IRRITATION AND DERMATITIS.
TESTS SHOW OVEREXPOSURE MAY CAUSE BLOOD DISORDERS AND NEUROLOGIC
DISORDERS. REPORTS HAVE ASSOCIATED REPEATED AND PROLONGED
OCCUPATIONAL OVEREXPOSURE TO S OLVENTS WITH PERMANENT BRAIN AND
NERVOUS SYSTEM DAMAGE. INTENTIONAL MISUSE OF THIS PRODUCT MAY BE
HARMFUL OR FATAL.

First Aid

First Aid:EYE: FLUSH W/WTR-15 MIN, HOLD LIDS OPEN. GET MED AID. SKIN:
WASH W/SOAP & WTR. RMV CONTAM CLOTHING & SHOES; DO NOT REUSE UNTIL
CLEANED. IF PERSISTENT IRRIT OCCURS, GET MED AID. INHAL: REMOVE TO
FRESH AIR/PROVIDE OXYGEN IF BREATH DIFFICULT.GIVE ARTIF RESP IF
NOT BREATHING. GET MED AID. IF SWALLOWED, SEEK EMERG MED ATTN. DO
NOT GIVE ANYTHING BY MOUTH TO UNCONSCIOUS PERSON. DO NOT INDUCE
VOMITING.

Fire Fighting

Flash Point Method:SCC
Flash Point:105F,41C
Lower Limits:1.0
Upper Limits:7.0
Extinguishing Media:DRY CHEMICAL, CARBON DIOXIDE, FOAM, WATER FOG.
Fire Fighting Procedures:EVAC AREA OF UNPROTECT PERSONNEL. WEAR PROPER
PROTECT CLOTH W/SCBA. COOL FIRE-EXPOS CNTNRS W/WTR. AVOID SPREADING
BURNING LIQ W/WTR USED FOR COOLING PURPOSES.
Unusual Fire/Explosion Hazard:THIS MATERIAL IS FLAMMABLE AND MAY BE
IGNITED BY HEAT, SPARKS, FLAME OR STATIC ELECTRICITY.

Accidental Release

Spill Release Procedures:STAY UPWIND/AWAY FROM SPILL. KEEP ALL SOURCES
OF IGNITION/HOT METAL SURFACES AWAY FROM SPILL. IF SPILL IS
INDOORS, VENTILATE AREA OF SPILL. IF LARGE SPILL: CALL SPILL
RESPONSE TEAM. NOTIFY APPROPRIATE STATE/LOCAL AGENCIES.

Handling

Handling and Storage Precautions:KEEP FROM HEAT/SPARKS/OPEN FLAME. KEEP
CNTNRS TIGHTLY CLSD. STORE AWAY FROM STRONG OXIDIZING AGENTS IN A
COOL, DRY PLACE W/ADEQUATE EXPLOSION-PROOF**
Other Precautions:DO NOT WELD, HEAT OR DRILL ON OR NEAR CONTAINER; EVEN
EMPTIED CONTAINERS CAN CONTAIN EXPLOSIVE VAPORS.

Exposure Controls

Respiratory Protection:DEPENDING ON THE NATURE AND CONCENTRATION OF THE
AIRBORNE MATERIAL, USE A RESPIRATOR OR GAS MASK WITH APPROPRIATE
CARTRIDGES AND CANNISTERS (NIOSH APPROVED, IF AVAILABLE) OR
SUPPLIED AIR EQUIPMENT.
Ventilation:USE EXPLOS-PROOF VENT AS REQ TO CONTROL VAPOR CONC. TO
MAINTAIN AIRBORNE CONC BELOW THE ESTABLISHED EXPOS LIMITS. #
Protective Gloves:IMPERVIOUS GLOVES
Eye Protection:CHEMICAL GOGGLES
Other Protective Equipment:WEAR PROTECTIVE CLOTHING AS REQUIRED TO
PREVENT SKIN CONTACT.
Work Hygienic Practices:WASH W/SOAP & WATER BEFORE
EATING/DRINKING/SMOKING/USING TOILET FACILITIES. LAUNDER
CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
**VENTILATION. GROUND EQUIPMENT TO PREVENT ACCUMULATION OF STATIC
CHARGE. IF POURING OR TRANSFERRING MATERIALS, CONTAINERS MUST BE
BONDED AND GROUNDED. #ADDITIONAL
VENTILAT ION OR EXHAUST SYSTEMS MAY BE REQUIRED.

Chemical Properties

HCC:F4
Boiling Pt:B.P. Text:212 - 395F
Vapor Density:>THAN AIR
Spec Gravity:12.2 LB/GL
Percent Volatiles by Volume:30.1

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:AVOID HEAT, SPARKS AND OPEN FLAME. AVOID
CONTACT WITH ALKALIES, AQUEOUS ACIDS, AMINES AND ACIDIC ALCOHOLS.
Hazardous Decomposition Products:THERMAL DECOMPOSITION IN THE PRESENCE
OF AIR MAY YIELD CARBON MONOXIDE AND/OR CARBON DIOXIDE.

Disposal

Waste Disposal Methods:DISPOSE OF PRODUCT IN ACCORDANCE WITH LOCAL,
COUNTY, STATE AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.